-40%

Omron H3CA-A Solid State Timer 24-240VAC New Surplus

$ 18.57

Availability: 13 in stock
  • Brand: Omron
  • MPN: H3CAA
  • Condition: New

    Description

    Omron H3CA-A Solid State Timer 24-240VAC New Surplus
    Rated supply voltage
    24 to 240 VAC (50/60 Hz)
    12 to 240 VDC (Ripple 20% max. (Single-phase full-wave rectified power sources may be used for 24 to 240 VDC.))
    Operating voltage range
    90 to 110% of rated supply voltage (21.6 to 264 VAC/10.8 to 264 VDC)
    Power consumption
    Approx. 0.2 to 4 VA/Approx. 0.2 to 2 W
    Time ranges(Number of ranges)
    7
    Time ranges
    0.1 to 99.9 s
    1 to 999 s
    0.1 to 99.9 min
    1 to 999 min
    0.1 to 99.9 h
    1 to 999 h
    10 to 9990 h
    Input method
    No-voltage input (open and short-circuit)
    Output modes
    A: ON delay
    B: Repeat cycle
    C: Signal ON/OFF delay
    D: Signal OFF delay
    E: Interval
    F: One shot and flicker
    G: Signal ON/OFF delay
    H: Signal OFF delay
    Control output (Contact output)
    Time-limit contact: SPDT
    Resistive load: 3 A at 250 VAC
    Minimum applicable load: 10 mA at 5 VDC (failure level: P Reference value)
    Reset system
    Self-reset/External reset
    Power reset
    Reset time: 0.5 s max.
    Display method
    LCD 3 digit
    Ambient temperature (Operating)
    -10 to 55 ℃ (with no icing)
    Ambient humidity (Operating)
    35 to 85%
    Accuracy of operating time
    ±0.3% ±0.05 s (The values are based on the set value.)
    Setting error
    ±0.5% ±0.05 s (The values are based on the set value.)
    Influence of voltage
    ±0.3% ±0.05 s (The values are based on the set value.)
    Influence of temperature
    ±0.3% ±0.05 s (The values are based on the set value.)
    Insulation resistance
    100 MΩ min. (at 500 VDC)
    Dielectric strength
    Between current carrying metal parts and non-current carrying metal parts: 2000 VAC 50/60 Hz 1 min
    Between control output terminals and operating circuit: 2000 VAC 50/60 Hz 1 min
    Between non-continuous contacts: 1000 VAC 50/60 Hz 1 min
    Impulse withstand voltage
    Between power terminals: 5 kV
    Between current carrying terminals and exposed non-current carrying metal parts: 5 kV
    Vibration resistance
    Destruction: 10 to 55 Hz, 0.75 mm single amplitude each in 3 directions for 1 hour
    Malfunction: 10 to 55 Hz, 0.5 mm single amplitude each in 3 directions for 10 min
    Shock resistance
    Destruction: 1,000 m/s
    2
    , 3 times each in 6 directions
    Malfunction: 100 m/s
    2
    , 3 times each in 6 directions
    Life expectancy
    Electrical: 100,000 operations min. (3 A at 250 VAC resistive load at 1800 operations/h)
    Mechanical: 10 million operations min. (under no load at 1,800 operations/h)
    Degree of protection
    IP40
    Mounting method
    Flush mounting / Surface mounting
    External connection method
    11-pin round socket
    Applicable socket
    P2CF-11, P2CF-11-E, P3GA-11, PL11
    Accessory (sold separately)
    Soft Cover: Y92A-48D
    Hard Cover: Y92A-48B
    Flush mounting adapter: Y92F-30/Y92F-70/Y92F-71
    Weight
    Approx. 110 g